Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
ACS Appl Mater Interfaces ; 16(12): 14583-14594, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38478505

RESUMO

Healing chronic diabetic wounds is challenging because of excessive reactive oxygen species (ROS) and hypoxia in the wound microenvironment. To address this issue, we propose a hydrogel wound dressing composed of polyethylene glycol (PEG) cross-linked with a biomimetic catalase, Fe-containing porphyrin (FeP) (i.e., FeP hydrogel). The immobilized FeP can serve as a catalyst for both ROS scavenging and O2 generation. The properties of the hydrogels were optimized by varying the composition ratios of the two constituent materials based on their mechanical properties and catalytic activity. Our in vitro cell experiments revealed that the FeP-80 hydrogel enhanced the proliferation and migration of keratinocytes and dermal fibroblasts and promoted the expression of angiogenic growth factors in keratinocytes. When tested with an in vivo diabetic chronic wound model, the FeP-80 hydrogel promoted wound healing by facilitating re-epithelialization, promoting angiogenesis, and suppressing inflammation, compared with other control groups.


Assuntos
Diabetes Mellitus , Hidrogéis , Humanos , Hidrogéis/farmacologia , Espécies Reativas de Oxigênio/metabolismo , Oxigênio , Cicatrização , Antibacterianos
2.
Opt Express ; 32(2): 1334-1341, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38297688

RESUMO

2 µm photonics and optoelectronics is promising for potential applications such as optical communications, LiDAR, and chemical sensing. While the research on 2 µm detectors is on the rise, the development of InP-based 2 µm gain materials with 0D nanostructures is rather stalled. Here, we demonstrate low-threshold, continuous wave lasing at 2 µm wavelength from InAs quantum dash/InP lasers enabled by punctuated growth of the quantum structure. We demonstrate low threshold current densities from the 7.1 µm width ridge-waveguide lasers, with values of 657, 1183, and 1944 A/cm2 under short pulse wave (SPW), quasi-continuous wave (QCW), and continuous wave operation. The lasers also exhibited good thermal stability, with a characteristic temperature T0 of 43 K under SPW mode. The lasing spectra is centered at 1.97 µm, coinciding with the ground-state emission observed from photoluminescence studies. We believe that the InAs quantum dash/InP lasers emitting near 2 µm will be a key enabling technology for 2 µm communication and sensing.

3.
Proc Natl Acad Sci U S A ; 120(51): e2315824120, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38096418

RESUMO

Adherence to medication plays a crucial role in the effective management of chronic diseases. However, patients often miss their scheduled drug administrations, resulting in suboptimal disease control. Therefore, we propose an implantable device enabled with automated and precisely timed drug administration. Our device incorporates a built-in mechanical clock movement to utilize a clockwork mechanism, i.e., a periodic turn of the hour axis, enabling automatic drug infusion at precise 12-h intervals. The actuation principle relies on the sophisticated design of the device, where the rotational movement of the hour axis is converted into potential mechanical energy and is abruptly released at the exact moment for drug administration. The clock movement can be charged either automatically by mechanical agitations or manually by winding the crown, while the device remains implanted, thereby enabling the device to be used permanently without the need for batteries. When tested using metoprolol, an antihypertensive drug, in a spontaneously hypertensive animal model, the implanted device can deliver drug automatically at precise 12-h intervals without the need for further attention, leading to similarly effective blood pressure control and ultimately, prevention of ventricular hypertrophy as compared with scheduled drug administrations. These findings suggest that our device is a promising alternative to conventional methods for complex drug administration.


Assuntos
Fontes de Energia Elétrica , Animais , Humanos , Preparações Farmacêuticas
4.
Biomater Res ; 27(1): 135, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38111009

RESUMO

BACKGROUND: Noninvasive monitoring of tear glucose levels can be convenient for patients to manage their diabetes mellitus. However, there are issues with monitoring tear glucose levels, such as the invasiveness of some methods, the miniaturization, inaccuracy, or the high cost of wearable devices. To overcome the issues, we newly designed a sucking disk-type (SD) strip biosensor that can quickly suck tear fluid and contains cerium oxide nanoparticle (CNP) that causes a unique color change according to the glucose level of the tear without complicated electronic components. METHODS: The SD strip biosensor composed of three distinct parts (tip, channel, and reaction chamber) was designed to contain the sensing paper, onto which tear fluid can be collected and delivered. The sensing paper treated with CNP/APTS (aminopropyltriethoxysilane) /GOx (glucose oxidase) was characterized. Then we carried out the reliability of the SD strip biosensor in the diabetic rabbit animals. We quantitatively analyzed the color values of the SD strip biosensor through the colorimetric analysis algorithm. RESULTS: We contacted the inferior palpebral conjunctiva (IPC) of a diabetic rabbit eye using an SD strip biosensor to collect tears without eye irritation and successfully verified the performance and quantitative efficacy of the sensor. An image processing algorithm that can optimize measurement accuracy is developed for accurate color change measurement of SD strip biosensors. The validation tests show a good correlation between glucose concentrations measured in the tear and blood. CONCLUSION: Our findings demonstrate that the CNP-embedded SD strip biosensor and the associated image processing can simply monitor tear glucose to manage diabetes mellitus.

5.
Biosens Bioelectron ; 238: 115571, 2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37562343

RESUMO

A microneedle (MN) sensor coated with a sensing composite material was proposed for measuring glucose concentrations in interstitial fluid (ISF). The sensing composite material was prepared by blending a polymer containing glucose-responsive phenylboronic acid (PBA) moieties (i.e., polystyrene-block-poly(acrylic acid-co-acrylamidophenylboronic acid)) with conductive carbon nanotubes (CNTs). The polymer exhibited reversible swelling behavior in response to glucose concentrations, which influenced the distribution of the embedded CNTs, resulting in sensitive variations in electrical percolation, even when coated onto a confined surface of the MN in the sensor. We varied the ratio of PBA moieties and the loading amount of CNTs in the sensing composite material of the MN sensor and tested them in vitro using an ISF-mimicking gel with physiological glucose concentrations to determine the optimal sensitivity conditions. When tested in animal models with varying blood glucose concentrations, the MN sensor coated with the selected sensing material exhibited a strong correlation between the measured electrical currents and blood glucose concentrations, showing accuracy comparable to that of a glucometer in clinical use.


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Animais , Polímeros , Glicemia , Líquido Extracelular , Técnicas Biossensoriais/métodos , Glucose
6.
Bioeng Transl Med ; 8(3): e10477, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37206221

RESUMO

Chemodynamic therapy (CDT) is based on the production of cytotoxic reactive oxygen species, such as hydroxyl radicals (•OH). Thus, CDT can be advantageous when it is cancer-specific, in terms of efficacy and safety. Therefore, we propose NH2-MIL-101(Fe), a Fe-containing metal-organic framework (MOF), as a carrier of Cu (copper)-chelating agent, d-penicillamine (d-pen; i.e., the NH2-MIL-101(Fe)/d-pen), as well as a catalyst with Fe-metal clusters for Fenton reaction. NH2-MIL-101(Fe)/d-pen in the form of nanoparticles was efficiently taken into cancer cells and released d-pen in a sustained manner. The released d-pen chelated Cu that is highly expressed in cancer environments and this produces extra H2O2, which is then decomposed by Fe in NH2-MIL-101(Fe) to generate •OH. Therefore, the cytotoxicity of NH2-MIL-101(Fe)/d-pen was observed in cancer cells, not in normal cells. We also suggest a formulation of NH2-MIL-101(Fe)/d-pen combined with NH2-MIL-101(Fe) loaded with the chemotherapeutic drug, irinotecan (CPT-11; NH2-MIL-101(Fe)/CPT-11). When intratumorally injected into tumor-bearing mice in vivo, this combined formulation exhibited the most prominent anticancer effects among all tested formulations, owing to the synergistic effect of CDT and chemotherapy.

7.
Bioeng Transl Med ; 8(3): e10479, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37206225

RESUMO

Prompt administration of first-aid drugs can save lives during medical emergencies such as anaphylaxis and hypoglycemia. However, this is often performed by needle self-injection, which is not easy for patients under emergency conditions. Therefore, we propose an implantable device capable of on-demand administration of first-aid drugs (i.e., the implantable device with a magnetically rotating disk [iMRD]), such as epinephrine and glucagon, via a noninvasive simple application of the magnet from the outside skin (i.e., the external magnet). The iMRD contained a disk embedded with a magnet, as well as multiple drug reservoirs that were sealed with a membrane, which was designed to rotate at a precise angle only when the external magnet was applied. During this rotation, the membrane on a designated single-drug reservoir was aligned and torn to expose the drug to the outside. When implanted in living animals, the iMRD, actuated by an external magnet, delivers epinephrine and glucagon, similar to conventional subcutaneous needle injections.

8.
Nanoscale Adv ; 5(5): 1316-1322, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36866266

RESUMO

We demonstrate the programmable light intensity of a micro-LED by compensating threshold voltage variability of thin-film transistors (TFTs) by introducing a non-volatile programmable ferroelectric material, HfZrO2 (HZO) into the gate stack of the TFT. We fabricated an amorphous ITZO TFT, ferroelectric TFTs (FeTFTs), and micro-LEDs and verified the feasibility of our proposed current-driving active matrix circuit. Importantly, we successfully present the programmed multi-level lighting of the micro-LED, utilizing partial polarization switching in the a-ITZO FeTFT. We expect that this approach will be highly promising for the next-generation display technology, replacing complicated threshold voltage compensation circuits with a simple a-ITZO FeTFT.

9.
Bioeng Transl Med ; 8(1): e10320, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36684080

RESUMO

Self-injectable therapy has several advantages in the treatment of metabolic disorders. However, frequent injections with needles impair patient compliance and medication adherence. Therefore, we develop a fully implantable device capable of on-demand administration of self-injection drugs via noninvasive manual button clicks on the outer skin. The device is designed to infuse the drug only at the moment of click actuation, which allows for an accurate and reproducible drug infusion, and also prevents unwanted drug leakage. Using a mechanical means of drug infusion, this implantable device does not contain any electronic compartments or batteries, making it compact, and semi-permanent. When tested in animals, the device can achieve subcutaneous injection-like pharmacokinetic and pharmacodynamic effects for self-injection drugs such as exenatide, insulin, and glucagon.

10.
Biomater Adv ; 145: 213268, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36580769

RESUMO

The potential therapeutic implications of nitric oxide (NO) have drawn a great deal of interest for reversing multidrug resistance (MDR) in cancer; however, previous strategies utilized unstable or toxic NO donors often oxidized by the excessive addition of reactive oxygen species, leading to unexpected side effects. Therefore, this study proposed a metal-organic framework (MOF), Porous coordination network (PCN)-223-Fe, to be loaded with a biocompatible NO donor, L-arginine (L-arg; i.e., PCN-223-Fe/L-arg). This specific MOF possesses a ligand of Fe-porphyrin, a biomimetic catalyst. Thus, with PCN-223-Fe/L-arg, L-arg was released in a sustained manner, which generated NO by a catalytic reaction between L-arg and Fe-porphyrin in PCN-223-Fe. Through this biomimetic process, PCN-223-Fe/L-arg could generate sufficient NO to reverse MDR at the expense of hydrogen peroxide already present and highly expressed in cancer environments. For treatment of MDR cancer, this study also proposed PCN-223-Fe loaded with an anticancer drug, irinotecan (CPT-11; i.e., PCN-223-Fe/CPT-11), to be formulated together with PCN-223-Fe/L-arg. Owing to the synergistic effect of reversed MDR by NO generation and sustained release of CPT-11, this combined formulation exhibited a higher anticancer effect on MDR cancer cells (MCF-7/ADR). When intratumorally injected in vivo, coadministration of PCN-223-Fe/L-arg and PCN-223-Fe/CPT-11 greatly suppressed tumor growth in nude mice bearing MDR tumors.


Assuntos
Antineoplásicos , Estruturas Metalorgânicas , Neoplasias , Animais , Camundongos , Estruturas Metalorgânicas/uso terapêutico , Óxido Nítrico/uso terapêutico , Irinotecano/uso terapêutico , Camundongos Nus , Biomimética , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias/tratamento farmacológico , Neoplasias/patologia , Doadores de Óxido Nítrico/uso terapêutico
11.
Opt Express ; 30(23): 42663-42677, 2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36366716

RESUMO

Conventional photon detectors necessarily face critical challenges regarding strong wavelength-selective response and narrow spectral bandwidth, which are undesirable for spectroscopic applications requiring a wide spectral range. With this perspective, herein, we overcome these challenges through a free-carrier absorption-based waveguide-integrated bolometer for infrared spectroscopic sensors on a silicon-on-insulator (SOI) platform featuring a spectrally flat response at near-infrared (NIR) range (1520-1620 nm). An in-depth thermal analysis was conducted with a systematic investigation of geometry dependence on the detectors. We achieved great performances: temperature coefficient of resistance (TCR) of -3.786%/K and sensitivity of -26.75%/mW with a low wavelength dependency, which are record-high values among reported waveguide bolometers so far, to our knowledge. In addition, a clear on-off response with the rise/fall time of 24.2/29.2 µs and a 3-dB roll-off frequency of ∼22 kHz were obtained, sufficient for a wide range of sensing applications. Together with the possibility of expanding an operation range to the mid-infrared (MIR) band, as well as simplicity in the detector architecture, our work here presents a novel strategy for integrated photodetectors covering NIR to MIR at room temperature for the development of the future silicon photonic sensors with ultrawide spectral bandwidth.

12.
ACS Appl Mater Interfaces ; 14(39): 45051-45058, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36162121

RESUMO

We report on the photoluminescence enhancement of 1.3 µm InAs quantum dots (QDs) epitaxially grown on an ultrathin 250 nm GaAs buffer on a Si substrate. Decreasing the GaAs buffer thickness from 1000 to 250 nm was found to not only increase the coalesced QD density from 6.5 × 108 to 1.9 × 109 cm-2 but also decrease the QD photoluminescence emission intensity dramatically. Inserting an Al0.4Ga0.6As potential barrier layer maintained strong photoluminescence from the QDs by effectively suppressing carrier leakage to the GaAs/Si interfacial region even when the GaAs buffer was thinned to 250 nm. We then fabricated a light-emitting diode using the ultrathin 250 nm GaAs buffer on Si and confirmed strong electroluminescence peaking at 1.28 µm without interfacial defect emission at room temperature. We believe that this work is promising for monolithically integrated evanescent Si lasers using InAs/GaAs QDs.

13.
ACS Appl Mater Interfaces ; 14(21): 24592-24601, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35580309

RESUMO

A charge trap device based on field-effect transistors (FET) is a promising candidate for artificial synapses because of its high reliability and mature fabrication technology. However, conventional MOSFET-based charge trap synapses require a strong stimulus for synaptic update because of their inefficient hot-carrier injection into the charge trapping layer, consequently causing a slow speed operation and large power consumption. Here, we propose a highly efficient charge trap synapse using III-V materials-based tunnel field-effect transistor (TFET). Our synaptic TFETs present superior subthreshold swing and improved charge trapping ability utilizing both carriers as charge trapping sources: hot holes created by impact ionization in the narrow bandgap InGaAs after being provided from the p+-source, and band-to-band tunneling hot electrons (BBHEs) generated at the abrupt p+n junctions in the TFETs. Thanks to these advances, our devices achieved outstanding efficiency in synaptic characteristics with a 5750 times faster synaptic update speed and 51 times lower sub-fJ/um2 energy consumption per single synaptic update in comparison to the MOSFET-based synapse. An artificial neural network (ANN) simulation also confirmed a high recognition accuracy of handwritten digits up to ∼90% in a multilayer perceptron neural network based on our synaptic devices.


Assuntos
Elétrons , Transistores Eletrônicos , Redes Neurais de Computação , Reprodutibilidade dos Testes , Sinapses
14.
Int J Pharm ; 618: 121664, 2022 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-35292393

RESUMO

A bolus of human growth hormone (hGH) is often prescribed for the treatment of growth hormone deficiency, which requires frequent injections in current clinical settings. This painful needle-involved delivery often results in poor patient compliance, leading to low medication adherence and poor clinical outcomes. Therefore, we propose a magnetically actuating implantable pump (MAP) that can infuse an accurate dose of hGH only at the time of non-invasive magnet application from the skin. The MAP herein could reproducibly infuse 20.6 ±â€¯0.9 µg hGH per actuation without any leak at times without actuation. The infused amount increased proportionally with an increase in the number of actuations. When the MAP was implanted and actuated with a magnet in animals with growth hormone deficiency for 21 days, the profiles of plasma hGH concentration and insulin-like growth factor (IGF)-1, as well as changes in body weight, were similar to those observed in animals treated with conventional subcutaneous hGH injections. Therefore, we anticipate that the MAP fabricated in this study can be a non-invasive alternative to administer hGH without repeated and frequent needle injections.


Assuntos
Hormônio do Crescimento Humano , Animais , Peso Corporal , Hormônio do Crescimento , Humanos , Injeções Subcutâneas , Fator de Crescimento Insulin-Like I , Adesão à Medicação
15.
Drug Deliv ; 29(1): 489-498, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35147052

RESUMO

For the prolonged, controlled delivery of systemic drugs, we propose an implantable drug-delivery chip (DDC) embedded with pairs of a microchannel and drug-reservoir serving as a drug diffusion barrier and depot, respectively. We pursued a DDC for dual drugs: a main-purpose drug, diclofenac (DF), for systemic exposure, and an antifibrotic drug, tranilast (TR), for local delivery. Thus, the problematic fibrotic tissue formation around the implanted device could be diminished, thereby less hindrance in systemic exposure of DF released from the DDC. First, we separately prepared DDCs for DF or TR delivery, and sought to find a proper microchannel length for a rapid onset and sustained pattern of drug release, as well as the required drug dose. Then, two distinct DDCs for DF and TR delivery, respectively, were assembled to produce a Dual_DDC for the concurrent delivery of DF and TR. When the Dual_DDC was implanted in living rats, the DF concentration in blood plasma did not drop significantly in the later periods after implantation relative to that in the early periods before fibrotic tissue formation. When the Dual_DDC was implanted without TR, there was a significant decrease in the blood plasma DF concentration as the time elapsed after implantation. Biopsied tissues around the Dual_DDC exhibited a significant decrease in the fibrotic capsule thickness and collagen density relative to the Dual_DDC without TR, owing to the effect of the local, sustained release of the TR.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Diclofenaco/farmacologia , Implantes de Medicamento/química , Fibrose/patologia , ortoaminobenzoatos/farmacologia , Animais , Anti-Inflamatórios não Esteroides/administração & dosagem , Anti-Inflamatórios não Esteroides/farmacocinética , Sobrevivência Celular/efeitos dos fármacos , Química Farmacêutica , Preparações de Ação Retardada , Diclofenaco/administração & dosagem , Diclofenaco/farmacocinética , Liberação Controlada de Fármacos , Ratos , Ratos Sprague-Dawley , ortoaminobenzoatos/administração & dosagem , ortoaminobenzoatos/farmacocinética
16.
ACS Appl Mater Interfaces ; 13(46): 55648-55655, 2021 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-34779602

RESUMO

Current infrared thermal image sensors are mainly based on planar firm substrates, but the rigid form factor appears to restrain the versatility of their applications. For wearable health monitoring and implanted biomedical sensing, transfer of active device layers onto a flexible substrate is required while controlling the high-quality crystalline interface. Here, we demonstrate high-detectivity flexible InAs thin-film mid-infrared photodetector arrays through high-yield wafer bonding and a heteroepitaxial lift-off process. An abruptly graded InxAl1-xAs (0.5 < x < 1) buffer was found to drastically improve the lift-off interface morphology and reduce the threading dislocation density twice, compared to the conventional linear grading method. Also, our flexible InAs photodetectors showed excellent optical performance with high mechanical robustness, a peak room-temperature specific detectivity of 1.21 × 109 cm-Hz1/2/W at 3.4 µm, and excellent device reliability. This flexible InAs photodetector enabled by the heteroepitaxial lift-off method shows promise for next-generation thermal image sensors.

17.
Micromachines (Basel) ; 12(6)2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34071362

RESUMO

The realization of a silicon optical phase shifter marked a cornerstone for the development of silicon photonics, and it is expected that optical interconnects based on the technology relax the explosive datacom growth in data centers. High-performance silicon optical modulators and switches, integrated into a chip, play a very important role in optical transceivers, encoding electrical signals onto the light at high speed and routing the optical signals, respectively. The development of the devices is continuously required to meet the ever-increasing data traffic at higher performance and lower cost. Therefore, heterogeneous integration is one of the highly promising approaches, expected to enable high modulation efficiency, low loss, low power consumption, small device footprint, etc. Therefore, we review heterogeneously integrated optical modulators and switches for the next-generation silicon photonic platform.

18.
ACS Appl Mater Interfaces ; 13(11): 13248-13253, 2021 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-33691400

RESUMO

Lightweight, flexible solar cells from III-V semiconductors offer new application opportunities for devices that require a power supply, such as cars, drones, satellites, or wearable devices, due to their outstanding efficiency and power-to-weight ratio (specific power). However, the specific power and stability of flexible photovoltaic (PV) devices need to be enhanced for use in such applications because current flexible PV devices are vulnerable to moisture and heat. Here, we develop ultra-lightweight, flexible InGaP/GaAs tandem solar cells with a dual-function encapsulation layer that serves as both a moisture barrier and an antireflection coating for the active device layer. Using a thin polymer film as a substrate and an ultrathin metal as a bonding layer, the total weight of the device is dramatically reduced. Therefore, the specific power of our solar cells is remarkably high with a value of over 5000 W/kg under the AM 1.5G solar spectrum. Additionally, there is no degradation even if the solar cells are exposed to harsh environmental conditions.

19.
Opt Express ; 28(24): 36559-36567, 2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33379747

RESUMO

We demonstrate flexible GaAs photodetector arrays that were hetero-epitaxially grown on a Si wafer for a new cost-effective and reliable wearable optoelectronics platform. A high crystalline quality GaAs layer was transferred onto a flexible foreign substrate and excellent retention of device performance was demonstrated by measuring the optical responsivities and dark currents. Optical simulation proves that the metal stacks used for wafer bonding serve as a back-reflector and enhance GaAs photodetector responsivity via a resonant-cavity effect. Device durability was also tested by bending 1000 times and no performance degradation was observed. This work paves a way for a cost-effective and flexible III-V optoelectronics technology with high durability.

20.
PLoS One ; 15(10): e0239317, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33027299

RESUMO

The present study demonstrated a noninvasive preocular sensor system for the concurrent monitoring of diabetes and one of its prevalent complications, dry eye syndrome (DES), using tear fluids. Two distinct sensors, i.e., the glucose and DES sensors, were prepared and encased together in a single housing unit to produce the sensor system, and the tip was designed to be in contact with the eye surface noninvasively to collect and deliver tear fluid to the sensors. The glucose sensor was modified from a commercially available electrochemical sensor to allow for the measurement of glucose concentrations, even in a small amount of collected tear fluid. The DES sensor was equipped with a microchannel spaced with two parallel electrodes to determine the amount of collected tear fluid. In vivo experimental results revealed that with the collected tear fluid of about 0.6-1.0 µl, the sensor system estimated the blood glucose concentrations with acceptable accuracy compared with that of the glucometer in clinical use. The DES condition in animals was diagnosed with high sensitivity (91.7%) and specificity (83.3%).


Assuntos
Técnicas Biossensoriais/métodos , Glicemia/análise , Síndromes do Olho Seco/diagnóstico , Lágrimas/química , Animais , Área Sob a Curva , Técnicas Biossensoriais/instrumentação , Eletrodos , Masculino , Curva ROC , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...